Ba1258B_RemoteRig_MkIIs-A33.docx
Microbit 2.0 AB 2010. All rights reserved
5 TDO - serial data 57600 bps from panel to radio
6 AF - audio to speaker.
The short 6 wire cable with RJ11 connectors supplied by Kenwood should be used between
the Radio and the Radio-RRC.
The long 6 wire cable with RJ11 connectors supplied by Kenwood should be used between the
Control-RRC and the control panel.
The short black CAT-6 patch cable attached with the Remoterig can be used as mic connection
between the Radio-RRC and the radio.
If the TS-480 is provided with a microphone with RJ-45 connector you can connect it directly
to the AUX/MIC connector on the Control-RRC. Older TS-480 has a circular 8 pin connector
then you have to use the adapter cable MJ-88 which was then supplied by Kenwood as a
adapter between the Microphone and the AUX/MIC connector.
Connection type 1
Modular 8-pol connector:
3 MIC- mic Signal
4 MICE - mic ground
5 PTT
6 GND PTT
Connection type 2
Modular 8-pol connector:
3 MIC- mic Signal
4 GND PTT
5 PTT
6 MICE - mic ground
If you use the wrong configuration everything will work but the system will be very sensitive
for HF (RFI).
Power supply
Control-RRC:
The Control-RRC is supplied with a common 13,8 V (10-18V) power supply. The display and
speaker amplifier needs a lot of power so you need at least 1A.
Radio-RRC:
The Radio-RRC could be powered with a separate Power supply or the same as the radio. If
you use the Radio PS make sure you have a 1A fuse on the output to the RRC. Do not connect
it direct to a 20-40A PS the cable will melt if something happens.
Comentarios a estos manuales